Clinical studies on shear wave elastography (SWE) of liver in healthy dogs


127 / 158

Authors

  • D. Sharma Guru Angad Dev Veterinary and Animal Sciences University, Ludhiana-141 004 (Punjab)
  • J. Mohindroo Guru Angad Dev Veterinary and Animal Sciences University, Ludhiana-141 004 (Punjab)
  • S.K. Mahajan Guru Angad Dev Veterinary and Animal Sciences University, Ludhiana-141 004 (Punjab)
  • T. Singh Guru Angad Dev Veterinary and Animal Sciences University, Ludhiana-141 004 (Punjab)
  • N. Kashyap Guru Angad Dev Veterinary and Animal Sciences University, Ludhiana-141 004 (Punjab)

Keywords:

Dog, Liver, Shear wave elastography (SWE)

Abstract

Shear wave elastography (SWE) has been documented as a useful tool for evaluating liver parenchyma in human medicine for diagnosis of chronic liver disorders including neoplasia. The aim of this study was to evaluate SWE of liver in healthy dogs. A total of 40 healthy dogs were included in this study. The most suitable acoustic windows for recording shear wave ultrasonography in dogs were established and documented on the basis of consistency of results, ease of recording SWE and animal compliance. The mean value of the SWE measurements of healthy liver in 40 dogs was 2.09±0.73 kPa for left liver lobes and 2.23±0.84 kPa for right liver lobes. The liver stiffness values obtained by SWE were not influenced by the gender and size of the animal. The mean value liver stiffness in dogs below 1 yr age group was significantly (Pd”0.01) lower than the dogs above 1 yr of age. It was concluded that left paracostal for left liver lobe in right lateral recumbency and right 11th-12th intercostal space for right liver lobe in left lateral recumbency were ideal windows for performing liver shear wave elastography in healthy dogs. The stiffness values of liver in healthy dogs range from 1.86-2.50 kPa.

Downloads

Download data is not yet available.

References

Aiello, S.E., Moses, M.A., Allen, D.G., Constable, P.D., Dart, A.D., Davies, P.R., Quessenberry, K.E., Reeves, P.T., Sharma, J.M. 2016. The Merck Veterinary Manual (11th edn.). Merck & Co., Inc Kenilworth, N J, USA. pp 3176-3177.

Arda, K., Ciledag, N., Arýbas, B.K., Aktas, E. and Köse, K. 2013. Quantitative assessment of the elasticity values of liver with shear wave ultrasonographic elastography. Indian J. Med. Res. 137: 911-915.

Barr, R.G., Ferraioli, G., Palmeri, M.L., Goodman, Z.D., Garcia-Tsao, G., Rubin, J., Garra, B., Myers, R.P., Wilson, S.R., Rubens, D. and Levine, D. 2015. Elastography assessment of liver fibrosis: Society of radiologists in ultrasound consensus conference statement. Radiol. 276: 845-861.

Bende, F., Mulabecirovic, A., Sporea, I., Popescu, A., Sirli, R., Odd, H.G., Mette, V. and Havre, R.F. 2018. Assessing liver stiffness by 2-D shearwave elastography in a healthy cohort. Ultrasound Med. Biol. 44: 332-341.

Castera, L., Forns, X. and Alberti, A. 2008. Noninvasive evaluation of liver fibrosis using transient elastography. J. Hepatol. 48: 835-847.

Suh, C.H., Kim, S.Y., Kim, K.W., Lim, Y.S., Lee, S.J., Lee, M.G., Lee, J., Lee, S.G. and Yu, E. 2014. Determination of normal hepatic elasticity by using real-time shear-wave elastography. Radiol. 271: 895-900.

Colombo, S., Belloli, L., Zaccanelli, M., Badia, E., Jamoletti, C., Buonocore, M. and Del Poggio, P. 2011. Normal liver stiffness and its determinants in healthy blood donors. Digest. Liver Dis. 43: 231- 236.

Conti, C.B., Cavalcoli, F., Fraquelli, M., Conte, D. and Massironi, S. 2016. Ultrasound elastographic techniques in focal liver lesions. World J. Gastroenterol. 22: 2647-2656.

Goddi, A., Bonardi, M. and Alessi, S. 2012. Breast elastography: A literature review. J. Ultrasound 15: 192-198.

Godshalk, C.P., Badertscher, R.R., Rppy, M.K. and Ghknt, A.W. 1988. Quantitative ultrasonic assessment of liver size in the dog. Vet. Radiol. 29: 162-167.

Guo, L.H., Wang, S.J., Xu, H.X., Sun, L.P., Zhang, Y.F., Xu, J.M., Wu, J., Fu, H.J. and Xu, X.H. 2-15. Differentiation of benign and malignant focal liver lesions: value of virtual touch tissue quantification of acoustic radiation force impulse elastography. Med. Oncol. 32: 68. doi: 10.1007/s12032-015-0543- 9.

Hartzband, L.E., Tidweij, A.S. and Lamb, C.R. 1989. Relative echogenicity of the renal cortex and liver in normal dogs. Paper presented to the American College of Veterinary Radiology, Annual Meeting, Breckenridge, CO, 1989 August 16-19.

Hawthorne, A.J., Booles, D., Nugent, P., Gettinby, G. and Wilkinson, J. 2004. Body-weight changes during growth of puppies of different breeds. J. Nutr. 134: 2027-2030.

Holdsworth, A., Bradley, K., Birch, S., Browne, W.J. and Barberet, V. 2014. Elastography of the normal canine liver, spleen and kidneys. Vet. Radiol. Ultrasound 55: 620-627.

Horster, S., Mandel, P., Zachoval, R. and Clevert, D.A. 2010. Comparing acoustic radiation force impulse imaging to transient elastography to assess liver stiffness in healthy volunteers with and without Valsalva maneuver. Clin. Hemorheol. Microcirc. 46:159-168.

James, K.K. 1999. Reference values in veterinary medicine. Lab. Med. 30: 194-197.

Jeon, S., Lee, G., Lee, S.K., Kim, H., Yu, D. and Choi, J. 2015. Ultrasonographic elastography of the liver, spleen, kidneys, and prostate in clinically normal beagle dogs. Vet. Radiol. Ultrasound 56: 425-431.

Lai, C.L., Ratziu, V., Yuen, M.F. and Poynard, T. 2003. Viral hepatitis B. Lancet 362: 2089-2094. Le Couteur, D.G. and McLean, A.J. 1998. The aging liver. Drug clearance and an oxygen diffusion barrier hypothesis. Clin. Pharmacokinet. 34: 359- 373.

Le Couteur, D.G., Warren, A., Cogger, V.C., Smedsrod, B., Sorenson, K.K., Cabo, R.D., Fraser, R. and Mccuskey, R.S. 2008. Old age and the hepatic sinusoid. Anat. Rec. (Hoboken) 291: 672-683.

Ling, W., Lu, Q., Quan, J., Ma, L. and Luo, Y. 2013. Assessment of impact factors on shear wave based liver stiffness measurement. Eur. J. Radiol. 82: 335- 341.

Ophir, J., Alam, S.K. and Garra, B. 2002. Elastography: imaging the elastic properties of soft tissues with ultrasound. J. Med. Ultrasonics 29: 155-171.

Park, H., Park, J.Y., Kim, D.Y., Ahn, S.H., Chon, C.Y., Han, K.H. and Kim, S.U. 2013. Characterization of focal liver masses using acoustic radiation force impulse elastography. World J. Gastroenterol. 19: 219-226.

Popescu, A., Sporea, I., Sirli, R., Bota, S., Focsa, M., Danila, M., Nicolita, D., Martie, A. Sendroiu, M. and Juchis, A. 2011. The mean values of liver stiffness assessed by acoustic radiation force impulse elastography in normal subjects. Med. Ultrason. 13: 33-37.

Poynard, T., Mathurin, P., Lai, C.L., Guyader, D., Poupon, R., Tainturier, M.H., Myers, R.P., Muntenau, M., Ratziu, V., Manns, M., Vogel, A., Capron, F., Chedid, A., Bedossa, P. and PANFIBROSIS Group. 2003. A comparison of fibrosis progression in chronic liver diseases. J. Hepatol. 38: 257- 265.

Roulot, D., Costes, J.L., Buyck, J.F., Warzocha, U., Gambier, N. and Czernichow, S. 2011. Transient elastography as a screening tool for liver fibrosis and cirrhosis in a community-based population aged over 45 years. Gut. 60: 977-984.

Sandulescu, L., Padureanu, V., Dumitrescu, C., Braia, N., Streba, C.T., Gheonea, D.I., Cazacu, S., Ciurea, T., Rogoveanu, I. and Saftoiu, A. 2012. A pilot study of real time elastography in the differentiation of focal liver lesions. Curr. Health Sci. J. 38: 32-35.

Sarvazyan, A., Hall, T.J., Urban, M.W., Fatemi, M., Aglyamov, S.R. and Garra, B.S. 2011. An overview of elastography: An emerging branch of medical imaging. Curr. Med. Imaging Rev. 7: 255-282.

Sirli, R., Bota, S., Sporea, I., Jurchis, A., Popescu, A., Gradinaru-Tasca¢u, O. and Szilaski, M. 2013. Liver stiffness measurements by means of supersonic shear imaging in patients without known liver pathology. Ultrasound Med. Biol. 9:1362-1367.

Son, C.Y., Kim, S.U., Han, W.K., Choi, G.H., Park, H., Yang, S.C., Choi, J.S., Park, J.Y., Kim do, Y., Ahn, S.H., Chon, C.Y. and Han, K.H. 2012. Normal liver elasticity values using acoustic radiation force impulse imaging: A prospective study in healthy living liver and kidney donors. J. Gastroenterol. Hepatol. 27: 130-136.

Sporea, I., Bota, S., Gra¢dinaru-Tas¸ca¢u, O.S., Irli, R. and Popescu, A. 2014. Comparative study between two point shear wave elastographic techniques: Acoustic radiation force impulse (ARFI) elastography and ElastPQ. Med. Ultrason. 16: 309-314.

Wells, P.N.T. and Liang, H. 2011. Medical ultrasound: imaging of soft tissue strain and elasticity. J. R. Soc. Interface 8: 1521-1549.

Wynne, H.A., Cope, L.H., Mutch, E., Rawlins, M.D., woodhouse, K.W. and James, O.F. 1989. The effect of age upon liver volume and apparent liver blood flow in healthy man. Hepatol. 9: 297-301.

Zhang, P., Zhou, P., Tian, S.M., Qian, Y., Deng, J. and Zhang, L. 2013. Application of acoustic radiation force impulse imaging for the evaluation of focal liver lesion elasticity. Hepatobiliary Pancreat. Dis Int. 12: 165-170.

Zoumpoulis, P.S., Mastorakou, E., Theotokas, I., Plagou, A. and Vafeiadis, E. 2011. Shear wave elastography for the evaluation of diffuse liver disease: Determining normal and pathological values in kPa. Ultrasound Med. Biol. 37: S58.

Submitted

2026-01-06

Published

2026-01-07

Issue

Section

Research Articles

How to Cite

Sharma, D., Mohindroo, J., Mahajan, S., Singh, T., & Kashyap, N. (2026). Clinical studies on shear wave elastography (SWE) of liver in healthy dogs. Indian Journal of Veterinary Surgery, 45(1), 1-6. https://epubs.icar.org.in/index.php/IJVS/article/view/174951