Evaluation of stainless steel and titanium miniplate systems for tibio-tarsus fracture stabilization in pigeons (Columba livia)


8 / 8

Authors

  • D. Jahangirbasha Karnataka Veterinary and Fisheries Sciences University, Bidar- 585 401 (Karnataka)
  • D. Dilipkumar Karnataka Veterinary and Fisheries Sciences University, Bidar- 585 401 (Karnataka)
  • B.V. Shivaprakash Karnataka Veterinary and Fisheries Sciences University, Bidar- 585 401 (Karnataka)
  • B. Bhagavantappa Karnataka Veterinary and Fisheries Sciences University, Bidar- 585 401 (Karnataka)
  • Kartik Bidari Karnataka Veterinary and Fisheries Sciences University, Bidar- 585 401 (Karnataka)
  • Gurudev Karajagi Karnataka Veterinary and Fisheries Sciences University, Bidar- 585 401 (Karnataka)
  • Syeda Mumtaz Karnataka Veterinary and Fisheries Sciences University, Bidar- 585 401 (Karnataka)

Keywords:

Miniplate, Osteosynthesis, Pigeon, Radiographic evaluation, Tibio-tarsus fracture

Abstract

Twelve pigeons (Columba livia) presented with tibio-tarsal fractures were randomly and equally divided into two groups and treated using a bone plating technique. In one group, a 1.3 mm, 6-hole stainless steel miniplate was used, while in the other a 1.3 mm, 6-hole titanium miniplate was used for fixation. Fixation was performed via open reduction and internal fixation (ORIF) under anaesthesia induced with xylazine HCl (3 mg/kg) and ketamine HCl (50 mg/kg). Clinical and radiographic healing were evaluated on days 7, 14, 28, 45, and 60. Fracture healing occurred through primary union in all cases. Weight bearing was achieved in all birds by day 10, and complete functional recovery was observed by day 21. Comparative evaluation revealed similar healing outcomes between the two groups; however, stainless steel miniplates were associated with fewer implant-related complications than titanium miniplates.

Downloads

Download data is not yet available.

References

Bauck, L., Fowler, J.D. and Cribb, P. 1987. Tibial osteotomy in an emu. Comp. Anim. Pract. 1: 26-30.

Bennert, B.M., Kircher, P.R., Gutbrod, A., Riechert, J. and Hatt, J.M. 2016. Evaluation of two miniplate systems and figure-of-eight bandages for stabilization of experimentally induced ulnar and radial fractures in pigeons (Columba livia). J. Avian Med. Surg. 30: 111-121.

Bennett, R.A. and Kuzma, A.B. 1992. Fracture management in birds. J. Zoo. Wild. Med. 23: 5-38.

Bush, M., Hughes, J.L., Ensley, P. and James, A.E. 1976. Fracture repair in exotics using internal fixation. J. Am. Anim. Hosp. Assoc. 12: 746-753.

Christen, C., Fischer, I., von Rechenberg, B., Flückiger, M. and Hatt, J.M. 2005. Evaluation of a maxillofacial miniplate compact 1.0 for stabiliz ation of the ulna in experimentally induced ulnar and radial fractures in pigeons (Columba livia). J. Avian Med. Surg. 19: 185-190.

Davidson, J.R., Mitchell, M.A. and Ramirez, S. 2005. Plate fixation of a coracoid fracture in a bald eagle (Haliaeetus leucocephalus). J. Avian Med. Surg. 19: 303-308.

Gouvea, A.S., Alievi, M.M., Noriega, V., Isis-dos, S.D., Pinto, T.M., De Menezes, C.L.M., Silva, R.B., Da Silva, L.M., Velasque, A.G., Pinto, L.A.T. and Coelho, A.J.A. 2011. Titanium microplates for treatment of tibio-tarsus fractures in pigeons. Cienc. Rural 41: 476-482.

Gull, J.M., Saveraid, T.C., Szabo, D. and Hatt, J.M. 2012. Evaluation of three miniplate systems for fracture stabilization in pigeons (Columba livia). J. Avian Med. Surg. 26: 203-212.

Guzman, D.S.M., Bubenik, L.J., Lauer, S.K., Vasanjee, S. and Mitchell, M.A. 2007. Repair of a coracoid luxation and a tibiotarsal fracture in a bald eagle (Haliaeetus leucocephalus). J. Avian Med. Surg. 21: 188-195.

Harcourt-Brown, N.H. 1996. Foot and leg problems. In: BSAVA Manual of Raptors, Pigeons and Waterfowl, Forbes, N.A. and Harcourt-Brown, N.H. (Eds). British Small Animal Association, Gloucestershire, UK. pp 147-168.

Helmer, P and Redig, P.T. 2006. Orthopedic disorders. Clin. Avian Med. 2: 761-774.

Kuzma, A.B. and Hunter, B. 1998. Osteotomy and derotation of the humerus in a turkey vulture using intramedullary polymethylmethacrylate and bone plate fixation. Can. Vet. J. 30: 900-901.

Langley-Hobbs, S.J., Voss, K., Lapish, J.P. and Montavon, P.M. 2009. Orthopedic implants. In: Feline Orthopedic Surgery and Musculoskeletal Disease, Montavon, P.M., Voss, K., Langley Hobbs, S.J. (Eds). Saunders Elsevier, London, UK. pp 259-282.

Levitt, L. 1989. Avian orthopedics. Compend. Contin. Educ. Pract. Vet. 11: 899-907.

Miller, A. 1998. Principles of fracture surgery. In: BSAVA Manual of Small Animal Fracture Repair and Management, Coughlan, A.R. and Miller, A. (Eds). Quedgeley, Gloucestershire, UK. pp 65-94.

Muller, M.G. and Nafeez, J.M. 2007. Use of the Fix Ex Tubulaire Type FESSA system for tibiotarsal fractures in falcons. Falco 29: 25-28.

Pallavi, Dilipkumar, D., Patil, M., Bhagavantappa, B. and Venkatgiri 2022. Tibiotarsus fracture repair by using titanium and stainless steel locking reconstruction bone plates in backyard poultry. J. Exp. Zool. India. 25: 273-277.

Venugopal, S.K., Anoop. S., Sarangom, S.B., Philip, S.B., Prakash, S., Joy, B. and Kankonkar, A.P. 2014. Repair and management of fractured wing in an Indian peafowl (Pave cristatus). Malaysian J. Vet. Res. 5: 15-19.

Von Werthern, C.J. and Bernasconi, C.E. 2000. Application of the maxillofacial mini-plate compact 1.0 in the fracture repair of 12 cats/2 dogs. Vet. Comp. Orthop. Traumatol. 13: 92-96.

Wan, P.Y., Adair, H.S., Pa on, C.S. and Faulk, D.L. 1994. Comparison of bone healing using polydioxanone and stainless-steel intramedullary pins in transverse, mi humeral osteotomies in pigeons (Columba livia). J. Zoo Wildlife. Med. 25: 264-269.

Wright, L., Mans, C., Olsen, G., Doss, G., Amene, E.W., Britsch, G., Christman, J. and Heatley, J. 2018. Retrospective evaluation of tibiotarsal fractures treated with tape splints in birds: 86 cases (2006 2015). J. Avian Med. Surg. 32: 205-209.

Submitted

2026-06-12

Published

2026-06-15

Issue

Section

Research Articles

How to Cite

Jahangirbasha, D., Dilipkumar, D., Shivaprakash, B., Bhagavantappa, B., Bidari, K., Karajagi, G., & Mumtaz, S. (2026). Evaluation of stainless steel and titanium miniplate systems for tibio-tarsus fracture stabilization in pigeons (Columba livia). Indian Journal of Veterinary Surgery, 47(01), 47-51. https://epubs.icar.org.in/index.php/IJVS/article/view/180073