Use of Continuous Glucose Monitoring system in Canine Diabetes


81 / 76

Authors

  • Chandrakant Narayanrao Galdhar Department of Veterinary Nuclear Medicine including Radio Isotope Laboratory, Mumbai Veterinary College, Parel-Mumbai-12
  • Gaikwad, R.V. Department of Veterinary Clinical Medicine, Ethics and Jurisprudence, Mumbai Veterinary College (MAFSU), Parel-Mumbai 400012

https://doi.org/10.56093/ijvm.v45i1.166796

Keywords:

Dog- diabetes- CGMS continuous glucose monitoring system

Abstract

Glycemic control is crucial for managing diabetes mellitus (DM) and preventing complications. Continuous glucose monitoring systems (CGMS) are commonly used in humans with DM, providing real-time glucose levels and detecting hyperglycemic and hypoglycemic episodes. CGMS are increasingly prescribed to diabetic dogs and cats due to their well-tolerated nature. This article describes the use of CGMS in a dog with diabetes.

Downloads

Download data is not yet available.

Author Biography

  • Chandrakant Narayanrao Galdhar, Department of Veterinary Nuclear Medicine including Radio Isotope Laboratory, Mumbai Veterinary College, Parel-Mumbai-12
    Assistant Professor and Radiological Safety Officer, Department of Veterinary Nuclear Medicine including Radio Isotope Laboratory, Mumbai Veterinary College, Parel-Mumbai-12

References

Corradini, S., Pilosio, B., Dondi, F., Linari, G., Testa, S., Brugnoli, F., Gianella, P., Pietra, M. and Fracassi, F. 2016. Accuracy of a flash glucose monitoring system in diabetic dogs. J. Vet. Intern. Med,. 30: 983–988.

Deiting, V. and Mischke, R. 2021. Use of the “FreeStyle Libre” glucose monitoring system in diabetic cats. Res. Vet. Sci., 135: 253–259.

Del Baldo, F., Fracassi, F., Pires, J., Tardo, A.M., Malerba, E., Manassero, E. and Gilor, C. 2021. Accuracy of a flash glucose monitoring system in cats and determination of the time lag between blood glucose and interstitial glucose concentrations. J. Vet. Intern. Med., 35: 1279–1287.

Malerba, E., Cattani, C., Del Baldo, F., Carotenuto, G., Corradini, S., Golinelli, S., Drudi, I. and Fracassi, F. 2020. Accuracy of a flash glucose monitoring system in dogs with diabetic ketoacidosis. J. Vet. Intern. Med., 34: 83–91.

Surman, S. and Fleeman, L. 2013. Continuous glucose monitoring in small animals. Vet. Clin. N. Am. Small Anim. Pract., 43: 381–406.

Tardo, A.M., Fleeman, L.M., Fracassi, F., Berg, A.S., Guarino, A.L. and Gilor, C. 2024. A dose titration protocol for once-daily insulin glargine 300 U/mL for the treatment of diabetes mellitus in dogs. J Vet Intern Med., 38(4):2120-2128.

Wiedmeyer, C.E. and Declue, A.E. 2008. Continuous glucose monitoring in dogs and cats. J. Vet. Intern. Med., 22: 2–8.

Downloads

Submitted

17-05-2025

Published

01-07-2025

How to Cite

Galdhar, C. N., & Gaikwad, R.V. (2025). Use of Continuous Glucose Monitoring system in Canine Diabetes. Indian Journal of Veterinary Medicine, 45(1). https://doi.org/10.56093/ijvm.v45i1.166796
Citation