Stray Current Corrosion of Copper Sheathing and Keel Cooling Pipe of a 36' Trawler
39 / 61
Abstract
The results of investigations into the cause of an accelerated
corrosion of copper sheathing and keel cooling pipe of a 36' wooden
trawler are reported. The corrosion is attributed to the stray electric
currents originating from the electrical wiring system. The sources of
stray currents and the remedial measures have been suggested.
Downloads
Download data is not yet available.
Downloads
Submitted
2016-03-16
Published
2025-06-05
Issue
Section
Articles
License
Copyright rests with the Society of Fisheries Technologists (India).How to Cite