Stray Current Corrosion of Copper Sheathing and Keel Cooling Pipe of a 36' Trawler


39 / 61

Authors

  • K. RAVINDRAN

https://doi.org/10.56093/ft.v5i2.56745

Abstract

The results of investigations into the cause of an accelerated
corrosion of copper sheathing and keel cooling pipe of a 36' wooden
trawler are reported. The corrosion is attributed to the stray electric
currents originating from the electrical wiring system. The sources of
stray currents and the remedial measures have been suggested.

Downloads

Download data is not yet available.

Downloads

Submitted

2016-03-16

Published

2025-06-05

How to Cite

RAVINDRAN, K. (2025). Stray Current Corrosion of Copper Sheathing and Keel Cooling Pipe of a 36’ Trawler. Fishery Technology, 5(2). https://doi.org/10.56093/ft.v5i2.56745
Citation