Innovative composite wall designs for evaporatively cooled structures for storage of perishables
210 / 72
Keywords:
Brick sand brick, Evaporatively cooled structures, Pervious concrete, Mesh supported fabricAbstract
The thermal performance of prototype evaporatively cooled (EC) structures using novel wall materials like pervious concrete (PC) and mesh supported fabric (MSF) were compared to a traditional brick-sand-brick (BSB) design. Structures were constructed at the Indian Agricultural Research Institute, Delhi and instrumented with thermocouples on the floor, on inner and outer surfaces of the walls and roof and in a 100 kg mass of simulated produce. The composite walls, roof, and floor were of unique designs and were made of specialized materials unused till now in EC structures. The thermal transmittance of the wall materials varied widely. Compared to BSB, average product temperatures over 5 days in June were approximately 2.5°C lower in PC and 3.5°C lower in MSF structures. The low thermal mass of the composite walls of MSF structure (almost 1/60th that of BSB walls), made the MSF structure cooler at night as it could follow the ‘cooler’ night air. Cost estimates for labour and materials suggested that PC and MSF structures would be 40 to 60% cheaper to construct than BSB structures.
Downloads
References
Chadha K L. 2001. Handbook of Horticulture, pp 1031. Indian Council of Agricultural Research, Directorate of Information and Publications of Agriculture, New Delhi, India.
Chopra S, Baboo B, Kudos Aleksha S K and Oberoi H S. 2001. Development of passive evaporative cooled room for on-farm storage of fruits and vegetables. (In) Proceedings of International Conference on Emerging Technologies in Airconditioning and Refrigeration. Agarwal R S (Ed). Allied Publishers Ltd., 26-28 September 2001, New Delhi, India, pp 265–73.
Chopra S, Kudos Aleksha S K, Oberoi H S, Baboo B, Ahmad K U M and Kaur J. 2004. Performance evaluation of evaporative cooled room for storage of kinnow. Journal of Food Science and Technology 41(5): 573–7.
Chopra S and Beaudry R. 2018. Redesigning evaporatively cooled rooms to incorporate solar powered refrigeration in India. Acta Horticulturae 1194: 609–15. DOI: https://doi.org/10.17660/ActaHortic.2018.1194.88
Chouksey R G. 1985. Design of passive ventilated and evaporatively cooled storage structures for potato and other semi perishables. Proc. Silver Jubilee Convention of ISAE,pp. 45-51. 29-31 October 1985. Bhopal, India, pp 45–51.
Dash S K. 1999. Studies on evaporatively cooled storage structures for horticultural produce. Ph D thesis, Division of Agricultural Engineering, Indian Agricultural Research Institute, New Delhi.
Roy S K and Khurdiya D S. 1986. Studies on evaporatively cooled zero energy input cool chamber for storage of horticultural produce. Indian Food Packer 40: 26–31.
Roy S K and Pal R K. 1994. A low-cost cool chamber: an innovative technology for developing countries (tropical fruits storage). International Conference on Agricultural Machinery and Equipment; Handling, Transport, Storage and Protection of Plant Products, 19 July 1993. Chiang Mai, Thailand.
Umbarkar S P, Borkar P A, Phirke P S, Kubde A B and Kale P B. 1998. Evaporatively cooled storage structure. Technical Bulletin No. 35, Dr. PDKV, Akola.
Vala K V, Saiyed F and Joshi D C. 2014. Evaporative cooled storage structures: An Indian scenario. Trends in Post-Harvest Technology 2: 22–32.
Downloads
Submitted
Published
Issue
Section
License
Copyright (c) 2018 The Indian Journal of Agricultural Sciences

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
The copyright of the articles published in The Indian Journal of Agricultural Sciences is vested with the Indian Council of Agricultural Research, which reserves the right to enter into any agreement with any organization in India or abroad, for reprography, photocopying, storage and dissemination of information. The Council has no objection to using the material, provided the information is not being utilized for commercial purposes and wherever the information is being used, proper credit is given to ICAR.