Effect of seasonal variation on the performance of solar photovoltaic pumping system under field conditions
226 / 130
Keywords:
Cloud effect, Conversion efficiency, Panel temperature, Smog effect, Solar photovoltaicAbstract
The present study was undertaken to analyse the performance of solar photovoltaic (SPV) pumping system parameters, under different seasons. The average flow rate in summer, monsoon, post-monsoon and winter season was 3.0, 2.17, 3.44 and 2.93 Lps, respectively. The average conversion efficiency in summer, monsoon, post-monsoon and winter season was 14.36, 15.13, 17.04 and 16.85%, respectively. The range of optimum panel temperature should be between 12–32°C at which conversion efficiency will be maximum varying from 18.39–21%. During smog the average solar irradiance and flow rate decreased from 828 W/m2 to 393 W/m2 and 3.09 Lps to 1.59 Lps, respectively, as compared to before smog conditions. The presence of clouds significantly affected/lowered down the current, RPM and flow rate but the temperature did not change much which reveals that temperature has minimum effect on the development of current and voltage in solar photovoltaic cells.Downloads
References
Agrawal N and KaIe V S. 2006.Optimal utilization of solar-photovoltaic water pumping system. Agricultural Engineering Today 30: 84–9.
Bather D M and Caruthers S P. 1981. Energy from agriculture; catch crops as a potential fuel source in the UK. ‘Proceedings of International seminar on energy conservation use of solar and other renewable energies agriculture’. Polytechnic of Central London, England. pp 9–22.
Garg S, Bhardwaj A, Taneja D S and Sondhi S K. 2013. Performance evaluation of solar photo voltaic (spv) pumping system under field conditions. Water and Energy International 70: 16–21.
Hamrouni N, Jraidi M and Cherif A. 2009 Theoretical and experimental analysis of the behaviour of a photovoltaic pumping system. Solar Energy 83:1335–44. DOI: https://doi.org/10.1016/j.solener.2009.03.006
Ministry of Power, GOI. 2018. Executive Summary Power Sector January-18. www.cea.nic.in/reports/monthly/ executivesummary/2018/exe_summary-01.pdf
Munir A, Ullah A, Ghani M U, Iqbal M and Ahmad M. 2012. Performance evaluation and simulation of a photovoltaic powered water pumping system. Pakistan Journal of Lifeand Social Science 10: 166–71.
Sumathy K, Venkatesh A and Sriramulu V. 1997. Effect of seasonal variation on the performance of a solar water pump. International Journal of Ambient Energy 18: 135–40. DOI: https://doi.org/10.1080/01430750.1997.9675272
Vasisht M S, Srinivasan J and Ramasesha S K. 2016. Performance of solar photovoltaic installations: Effect of seasonal variations. Solar Energy 131:39–46. DOI: https://doi.org/10.1016/j.solener.2016.02.013
Downloads
Submitted
Published
Issue
Section
License
Copyright (c) 2019 The Indian Journal of Agricultural Sciences

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
The copyright of the articles published in The Indian Journal of Agricultural Sciences is vested with the Indian Council of Agricultural Research, which reserves the right to enter into any agreement with any organization in India or abroad, for reprography, photocopying, storage and dissemination of information. The Council has no objection to using the material, provided the information is not being utilized for commercial purposes and wherever the information is being used, proper credit is given to ICAR.