REDUCTION IN SEEPAGE RATE AND STORAGE CAPACITY OF A DUGOUT POND-A CASE STUDY
25
Abstract
In a study, it was observed that the seepage rate from a dugout pond was reduced to 7 cm day -4 after a span of 12 years from the original seepage rate of 12 cm day-1. This was due to the natural silting in the tank area. However; it was observed that the reduction in storage capacity at higher rate was mainly because of excess siltation due to dismantling of inlet concrete structure.
Submitted
2022-11-28
Published
2022-11-28
Issue
Section
Articles
License
On publication in JSWC, the copyrights on the full contents of the paper will be of Soil Conservation Society of India, New Delhi.How to Cite