Application of anatomically contoured intramedullary interlocking nailing for fixation of femoral diaphyseal fractures in dogs


556 / 149

Authors

  • SAKSHI SAKSHI CSK Himachal Pradesh Krishi Vishvavidyalaya, Palampur, Himachal Pradesh 176 062 India
  • S P TYAGI CSK Himachal Pradesh Krishi Vishvavidyalaya, Palampur, Himachal Pradesh 176 062 India
  • AMIT KUMAR CSK Himachal Pradesh Krishi Vishvavidyalaya, Palampur, Himachal Pradesh 176 062 India
  • ADARSH KUMAR CSK Himachal Pradesh Krishi Vishvavidyalaya, Palampur, Himachal Pradesh 176 062 India
  • SUKHPREET SINGH CSK Himachal Pradesh Krishi Vishvavidyalaya, Palampur, Himachal Pradesh 176 062 India
  • ARVIND KUMAR CSK Himachal Pradesh Krishi Vishvavidyalaya, Palampur, Himachal Pradesh 176 062 India

https://doi.org/10.56093/ijans.v92i3.122254

Keywords:

Diaphyseal, Dog, Femur, Fracture, Interlock nailing, Intramedullary

Abstract

The study was conducted on 10 client-owned dogs of either sex presented for fixation of femoral diaphyseal fractures. After thorough clinical, orthopaedic and radiographic examinations, the patients were subjected to application of specially-designed anatomically contoured intramedullary interlocking nailing (ACIILN) for fixation of fractures. All the fractures were closed and involved mid (n=9) to slightly distal (n=1) diaphysis. The diameter of used ACIILN ranged from 5–7 mm and the length from 11–15 cm. All the ACIILN were applied in static fashion with at least 2 screws each in both proximal and distal fracture fragments. The duration of surgery for application of ACIILN ranged from 35–75 min. The technique was found to be moderately difficult with extent of tissue manipulation in the category of low to moderate. Pain and inflammation decreased gradually in all the cases in an anticipated manner.With gradual improvement in weight-bearing capability, the limb function was restored in all cases quiet fast in the postoperative period. More amount of the callus formed over medial and caudal surfaces indicating less amount of stability at these surfaces. Anatomically contoured intramedullary interlocking nailing technique provided clinically viable fracture fixation technique resulting into early limb function.

Downloads

Download data is not yet available.

References

Arican M, Alkan F, Altan S, Parlak K and Yavru N. 2017. Clinical experience of interlocking nail stabilization of long bone fractures in dogs—A retrospective study of 26 cases. Israel Journal of Veterinary Medicine 72: 45–50.

Durall I and Diaz M C. 1996. Early experience with the use of an interlocking nail for the repair of canine femoral shaft fractures. Veterinary Surgery 25: 397–406. DOI: https://doi.org/10.1111/j.1532-950X.1996.tb01434.x

Duhautois B. 2003. Use of veterinary interlocking nail for diaphyseal fractures in dogs and cats. 121 cases. Veterinary Surgery 32: 8–20. DOI: https://doi.org/10.1053/jvet.2003.50008

Déjardin L M and Cabassu J P. 2005. Femoral fractures in young dogs. AO Dialogue 3: 39–43.

Harasen G. 2003. Common long bone fractures in small animal practice–Part 1. Canadian Veterinary Journal 44: 333–34.

Ikem I C, Ogunlusi J D and Ine H R. 2007. Achieving interlocking nails without using an image intensifier. International Orthopaedics 31: 487–90. DOI: https://doi.org/10.1007/s00264-006-0219-3

Newton and Nunamaker D M. 1985. Methods of internal fixation. Textbook of Small Animal Orthopaedics. (Eds) Newton C D and Nunamaker D M. International Veterinary Information Service, Ithaca, New York, USA.

Kumar H. 2016. ‘Comparative evaluation of different fixation techniques for fixation of femoral fractures in dogs’. M.V.Sc.

Thesis, Department of Veterinary Surgery and Radiology, CSK Himachal Pradesh Krishi Vishvavidyalaya, Palampur, India.

Kaur J. 2017. ‘Evaluation of interlocking nailing technique for fixation of long bone fractures in small animals’. M.V.Sc.

Thesis, Department of Veterinary Surgery and Radiology, CSK Himachal Pradesh Krishi Vishvavidyalaya, Palampur, India. Raghunath M and Singh S S. 2002. Intramedullary interlocking nailing (ILN) for long bone fracture fixation in dogs using indigenously designed equipments. Indian Journal of Veterinary Surgery 23: 89.

Wheeler J L, Lewis D D, Cross A R, Stubbs W P and Parker R B. 2004. Intramedullary interlocking nail fixation in dogs and cats: Clinical applications. Compendium: Continuing Education for Veterinarians (Small animals) 26: 531–44.

Downloads

Submitted

2022-03-15

Published

2022-03-15

Issue

Section

Review Article

How to Cite

SAKSHI, S., TYAGI, S. P., KUMAR, A., KUMAR, A., SINGH, S., & KUMAR, A. (2022). Application of anatomically contoured intramedullary interlocking nailing for fixation of femoral diaphyseal fractures in dogs. The Indian Journal of Animal Sciences, 92(3), 283-288. https://doi.org/10.56093/ijans.v92i3.122254
Citation