Use of supracutaneous bone plating for management of radius/ulna and tibia/fibula fractures in dogs
286 / 312
Keywords:
Biological osteosynthesis, Dogs, Fractures, Supracutaneous bone platingAbstract
The study was done with the objective to utilize supracutaneous bone plating as a mean of minimally invasive osteosynthesis for management of radius/ulna and tibia/fibula fractures in dogs. Nine cases of long bone fracture (2 radius/ulna and 7 tibia/fibula fracture) in dogs having body weight 8-20 kg and age 4 months to 2 years were repaired with supracutaneous bone plating (minimally invasive plate osteosynthesis) under general anaesthesia after a thorough physical, orthopaedic, neurological and radiographic examinations. Intra-operatively, 3.5 mm, locking head-limited contact-dynamic compression plate (LH-LC-DCP) was used in locking mode with insertion of two self-tapping locking head cortical screws of 3.5 mm (of varying length) in each proximal as well as distal fracture. The bone plate was applied on the medial surface of radius and tibia. Postoperative radiographs were taken to assess
the status of fracture reduction and fixation which was good in all the cases. Regular follow-ups showed good fracture reduction as well as fixation with no changes in implant position. Loosening of screws was observed in single case with no other complication in any of the cases. All the implants were removed on or before 68th day after surgery under sedation. All the animals showed good weight bearing with near to normal limb function on final day of the reappraisal. The supracutaneous bone constructs provided good reduction and fixation at fracture site similar as external skeletal fixators not compromising on axial and torsional stiffness.
Downloads
References
Ang B F H, Chen J Y, Yew A K S, Chua S K, Chou S M, Chia S L, Koh J S B and Howe T S. 2017. Externalised locking compression plate as an alternative to the unilateral external fixator: A biomechanical comparative study of axial and torsional stiffness. Bone and Joint Research 6(04): 216–23. DOI: https://doi.org/10.1302/2046-3758.64.2000470
Cronier P, Pietu G, Dujardin C, Bigorre N, Ducellier F and Gerard R. 2010. The concept of locking plates. Orthopaedics and Traumatology: Surgery and Research 965: 517–36. DOI: https://doi.org/10.1016/j.otsr.2010.03.008
He X, Zhang J, Li M, Yu Y and Zhu L. 2014. Treatment of segmental tibial fractures with supercutaneous plating. Orthopedics 37(08): 712–16. DOI: https://doi.org/10.3928/01477447-20140728-57
Kerkhoffs G M, Kuipers M M, Marti R K and Van der Werken C. 2003. External fixation with standard AO-plates: technique, indications, and results in 31 cases. Journal of Orthopaedic Trauma 17(01): 61–64. DOI: https://doi.org/10.1097/00005131-200301000-00010
Kloen P. 2009. Supercutaneous plating: Use of a locking compression plate as an external fixator. Journal of Orthopaedic Trauma 23(01): 72–75. DOI: https://doi.org/10.1097/BOT.0b013e31818f8de4
Klos Z, Ratajska-Michalczak K and Steet. 1995. Zespol stabilizer in the treatment of open fractures of the zeugopodium in dogs and a goat. (Eds) Kossowsky R, Kossovsky. Advances in Materials Science and Implant Orthopaedic Surgery. 1st ed. Springer, New York. Pp 73–81. DOI: https://doi.org/10.1007/978-94-011-0157-8_6
Mizuno K, Mineo K, Tachibana T, Sumi M, Matsubara T and Hirohata K. 1990. The osteogenetic potential of fracture haematoma. Subperiosteal and intramuscular transplantation of the haematoma. Journal of Bone and Joint Surgery 72(05): 822–29. DOI: https://doi.org/10.1302/0301-620X.72B5.2211764
Nicetto T and Longo F. 2019. Supercutaneous plating for the treatment of traumatic injuries of the appendicular skeleton in dogs. Veterinary and Comparative Orthopaedics and Traumatology 32(2): 149–57. DOI: https://doi.org/10.1055/s-0038-1676457
Nicetto T and Longo F. 2017. Supracutaneous plating using a locking plate for the treatment of a tibial fracture in a cat. Canadian Veterinary Journal 58(06): 585–90.
Palmer R H. 1999. Biological osteosynthesis. Veterinary Clinics of North America: Small Animal Practice 29(05): 1171–85. DOI: https://doi.org/10.1016/S0195-5616(99)50108-3
Petazzoni M, Urizzi A, Verdonck B and Jaeger G. 2010. Fixing internal fixator: Concept and technique. Veterinary and Comparative Orthopaedics and Traumatology 23(04): 250–53. DOI: https://doi.org/10.3415/VCOT-09-10-0108
Qiu X S, Yuan H, Zheng X, Wang J F, Xiong J and Chen Y X. 2014. Locking plate as a definitive external fixator for treating tibial fractures with compromised soft tissue envelop. Archives of Orthopaedic and Trauma Surgery 134(03): 383-88. DOI: https://doi.org/10.1007/s00402-013-1916-1
Sakshi. 2019. ‘Anatomically contoured intramedullary interlocking nailing for fixation of femoral fractures in dogs.’ M.V.Sc. Thesis, Department of Veterinary Surgery and Radiology, CSK Himachal Pradesh Krishi Vishvavidyalaya, Palampur, India.
Singh S. 2021. ‘Diagnosis and management of long bone fractures in dogs.’ M.V.Sc. Thesis, Department of Veterinary Surgery and Radiology, CSK Himachal Pradesh Krishi Vishvavidyalaya, Palampur, India.
Tobias K. 1990. Manual of Small Animal Soft Tissue Surgery. 2nd ed. Wiley-Blackwell, Iowa, USA.
Tulner S A F, Strackee S D and Kloen P. 2012. Metaphyseal locking compression plate as an external fixator for the distal tibia. International Orthopaedics 36(09): 1923–27. DOI: https://doi.org/10.1007/s00264-012-1585-7
Woon C Y, Wong M K and Howe T S. 2010. LCP external fixation–external application of an internal fixator: Two cases and a review of the literature. Journal of Orthopaedic Surgery and Research 5:19. DOI: https://doi.org/10.1186/1749-799X-5-19
Downloads
Submitted
Published
Issue
Section
License
Copyright (c) 2023 The Indian Journal of Animal Sciences

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
The copyright of the articles published in The Indian Journal of Animal Sciences is vested with the Indian Council of Agricultural Research, which reserves the right to enter into any agreement with any organization in India or abroad, for reprography, photocopying, storage and dissemination of information. The Council has no objection to using the material, provided the information is not being utilized for commercial purposes and wherever the information is being used, proper credit is given to ICAR.