Comparative efficacy of passive and mechanical fan-pad cooling system for microclimate modification and welfare in broiler production


281 / 79

Authors

  • S S CHIB Guru Angad Dev Veterinary and Animal Science University, Ludhiana, Punjab 141 004 India
  • A SHARMA Guru Angad Dev Veterinary and Animal Science University, Ludhiana, Punjab 141 004 India
  • Y SINGH Guru Angad Dev Veterinary and Animal Science University, Ludhiana, Punjab 141 004 India
  • A P S SETHI Guru Angad Dev Veterinary and Animal Science University, Ludhiana, Punjab 141 004 India
  • A L SAINI Guru Angad Dev Veterinary and Animal Science University, Ludhiana, Punjab 141 004 India
  • C SINGH Guru Angad Dev Veterinary and Animal Science University, Ludhiana, Punjab 141 004 India

https://doi.org/10.56093/ijans.v86i7.59955

Keywords:

Broiler welfare, Heat stress, Mechanical cooling, Microclimate modification, Passive cooling

Abstract

Efficacy of passive cooling vis-à-vis mechanical fan-pad cooling system was assessed for microclimate modification to alleviate heat stress and improving growth performance and welfare of broilers. Cooling treatments comprised of Tc (control without any cooling system), TJSC passive cooling (jute sheet roof shading and curtains with gravity flow sprinklers), TGSC passive cooling (green sheet roof shadings and curtains with gravity flow sprinklers) and TFP (fan pad mechanical cooling systems). The results of shed microclimate indicated that maximum ambient temperature, temperature humidity index (THI) and duration and level of heat stress in control were significantly higher than passive (TJSC and TGSC) and mechanical (TFP) cooling group. Growth performance and feed efficiency, in both passive (TJSC and TGSC) and mechanical cooling (TFP) were significantly better than control. However, growth performance and feed efficiency of chicks was significantly higher in TFP than chicks in passive (TJSC and TGSC) cooling groups. In passive cooling systems (TJSC and TGSC), the plasma catalase, glutathione peroxidase (GPx) and BUN were significantly lower than control (Tc) but significantly higher than mechanical cooling (TFP) system. The stress related behavioural activities, panting, preening, scratching and wing flapping were significantly higher in control as than in cooling system. It was concluded that passive cooling system can be an environment friendly and energy independent alternate to intensive mechanical cooling system to reduce heat stress and improve growth and welfare in broiler production.

Downloads

Download data is not yet available.

References

Anonymous. 2012. 19th Livestock Census 2012, All India Report. Pp 109. Ministry of Agriculture, Department of Animal Husbandry, Dairying and Fisheries, Government of India, New Delhi.

Altan O, Pabuccuoqlu A, Altan, Konyalioqlu S and Bayraktar H. 2003. Effect of heat stress on oxidative stress, lipid peroxidation and some stress parameters in broilers. British Poultry Science 44: 545–50. DOI: https://doi.org/10.1080/00071660310001618334

Bayraktar H, Artukoglu M and Altan A. 2004. Evaluation of the pad cooling system effectiveness used in hot weather conditions in broiler houses: Izmir case study. Hayvansal Uretim. Journal of Animal Production 45: 1–9.

Bonnet S, Geraert P A, Lessire M, Carre B and Guillaumin S. 1997. Effect of high ambient temperature on feed digestibility in broilers. Poultry Science 76: 857–63. DOI: https://doi.org/10.1093/ps/76.6.857

Dagtekin M, Karaca C and Yildiz Y. 2009. Long axis heat distribution in a tunnel ventilated broiler house equipped with an evaporative pad cooling system. Animal Production Science 49 (12): 1125–31. DOI: https://doi.org/10.1071/EA08077

Geetha N B and Velraj R. 2012. Passive cooling method for energy efficient building with and without thermal energy storage- A review. Energy Education Science and Research 29 (2): 913–

Gupta R. 2012. ‘Effect of different cooling systems on the performance of broiler chicks.’ M.V.Sc. Thesis, Guru Angad Dev Veterinary and Animal Science University, Ludhiana, India.

Gupta R, Kaur D, Chopra S, Nagra S S, Rai D R and Patil R T. 2014. Performance analysis of the broiler chicks under different cooling devices during hot dry summer. Indian Journal of Animal Research 48 (5): 480–85. DOI: https://doi.org/10.5958/0976-0555.2014.00015.6

IPCC. 2014. Climate Change 2014. Synthesis Report. Contribution of Working Groups I, II and III to the Fifth Assessment Report of the Intergovernmental Panel on Climate Change. (Eds) Pachauri R K and Meyer L A. IPCC, Geneva, Switzerland, pp 151.

Kamal M A. 2012. An Overview of passive cooling techniques in buildings: Design concepts and architectural interventions. Acta Technica Napocensis: Civil Engineering & Architecture 55 (1): 84–97.

Lin Y, Ggaoyi T, YuQiang F, JinHai F and MinHong Z. 2010. Effects of acute heat stress and subsequent stress removal on function of hepatic mitochondrial respiration, ROS production and lipid peroxidation in broiler chickens. Comparative Biochemistry and Physiology C, Toxicology and Pharmacology 151 (2): 204–08. DOI: https://doi.org/10.1016/j.cbpc.2009.10.010

Petek M, Dimken S and Ogan M M. 2013. Performance analysis of a two stage pad cooling system in broiler houses. Tubitak Journal of Veterinary and Animal Sciences 36 (1): 21–26. DOI: https://doi.org/10.3906/vet-1101-755

Mack LA, Felver-Gant, JN Dennis, R L Cheng, H W. 2013. Genetic variation alter production and behavioral responses following heat stress in 2 strains of laying hens. Poultry Science 92 : 285–94. DOI: https://doi.org/10.3382/ps.2012-02589

Purswell J L, Dozier W A, Olanrewaju H A Davies J D, Xin H and Gates R S. 2012. Effect of temperature humidity index on live performance in broiler chickens grown from 49 to 63 days of age. Agricultural and Biosystems Engineering Conference Proceeding and Presentation. Pp: 12–265.

Tao X and Xin H. 2003. Temperature humidity index for market size broilers. The Society for Engineering in Agricultural, Food and Biological System. Pp: 34037.

Xin H, Berry I L, Tabler G H and Barton I L. 1994. Temperature and humidity profiles of broiler houses with experimental conventional and tunnel ventilation systems. Applied Engineering in Agriculture 10 (4): 535–42. DOI: https://doi.org/10.13031/2013.25883

www.heatstress.info. Heat Stress in Livestock and Poultry. Ruth Consolidated Industries Poultry Ltd, Australia

Downloads

Submitted

2016-07-15

Published

2016-07-15

Issue

Section

Articles

How to Cite

CHIB, S. S., SHARMA, A., SINGH, Y., SETHI, A. P. S., SAINI, A. L., & SINGH, C. (2016). Comparative efficacy of passive and mechanical fan-pad cooling system for microclimate modification and welfare in broiler production. The Indian Journal of Animal Sciences, 86(7), 810–815. https://doi.org/10.56093/ijans.v86i7.59955