The study included 14 cases of femur fracture in which two different techniques namely intramedullary interlocking nailing (IILN) (group-I; 9 cases) and end threaded pinning (ETP) (group-II; 5 cases) were used for fixation of the fracture. The mean duration of surgical procedure was higher in group I as compared to group II. The extent of manipulation/soft tissue damage was slightly more in group I than in group II. The technique of IILN was relatively more difficult than ETP. The extent of fracture reduction and fixation was relatively better in group I than in group II. The weight-bearing improved gradually in both the groups but found to be better in group I than group II. The functional outcome of the fractured limb was superior in fracture fixed by IILN as compared to other group.Downloads
References
Beale B. 2004. Orthopedic clinical techniques femur fracture repair. Clinical Techniques in Small Animal Practice 19: 134– 150. DOI: https://doi.org/10.1053/j.ctsap.2004.09.006
Brinker O, Piermattei L D and Flo G L. 2015. Handbook of Small Animal Orthopedics and Fracture Repair. 5th Edition. Elsevier, Inc.
Chanana M, Kumar A, Tyagi S P, Singla A K, Sharma A and Farooq U B. 2018. End threaded intramedullary positive profile screw ended self-tapping pin (Admit pin)-A cost effective novel implant for fixing canine long bone fractures. Veterinary World 11: 181–85. DOI: https://doi.org/10.14202/vetworld.2018.181-185
Eyarefe O D and Oyetayo S N. 2016. Prevalence and pattern of small animal orthopaedic conditions at the veterinary teaching hospital, University of Ibadan. Sokoto Journal of Veterinary Sciences 14: 8–15. DOI: https://doi.org/10.4314/sokjvs.v14i2.2
Harasen G. 2011. Orthopedic hardware and equipment for the beginner: Part 1. Pins and wires. Canadian Veterinary Journal 52: 1025–26.
Newton and Nunamaker D M. 1985. Methods of Internal Fixation. Textbook of Small Animal Orthopaedics. (1st Eds) C D Newton and D M Nunamaker. International Veterinary Information Service, Ithaca, New York, USA.
Raghunath M. 2002. ‘Studies on intramedullary interlocking nailing and dynamic compression plating on long bone fracture fixation in dogs’. PhD Thesis. Department of Veterinary Surgery and Radiology, Punjab Agricultural University, Ludhiana, India.
Raghunath M, Bishnoi A K, Singh S S, Singh M, Sharma A and Atri K. 2012. Management of segmental fractures of tibia and femur by static intramedullary interlocking nailing in twelve dogs. International Journal of Applied Research in Veterinary Medicine 10: 264–72.
Saravanan K B, Maiti S K, Singh G R, Hoque M, Kumar N and Setia H C. 2004. Complication associated with different internal fixation techniques in the management of comminuted femoral fracture in dog. Indian Journal of Animal Sciences 74: 1128–29.
Wheeler J L, Lewis D D, Cross A R, Stubbs W P and Parker R B. 2004. Intramedullary interlocking nail fixation in dogs and cats: clinical applications. Compendium on Continuing Education for the Practicing Veterinarian 26: 531–44.
Downloads
Submitted
Published
Issue
Section
License
The copyright of the articles published in The Indian Journal of Animal Sciences is vested with the Indian Council of Agricultural Research, which reserves the right to enter into any agreement with any organization in India or abroad, for reprography, photocopying, storage and dissemination of information. The Council has no objection to using the material, provided the information is not being utilized for commercial purposes and wherever the information is being used, proper credit is given to ICAR.